4
Mechanical installation
Permitted mounting position
Operating Instructions – CMP ELVCD
19
4.4
Permitted mounting position
The ELVCD drive is mounted in the system. Observe the mounting position specified
on the motor nameplate.
4.5
Installing the ELVCD drive
4.5.1
Notes
•
When mounting close to the motor, it must be ensured that the ID on the name-
plate of the motor is identical to the ID on the "nameplate of the inverter" (→
16).
•
Only install the ELVCD drive on a level, low-vibration, and torsionally rigid support
structure.
•
Thoroughly remove any anti-corrosion agent from the shaft end. Use a commer-
cially available solvent. Do not allow the solvent to penetrate the bearings and
sealing rings – this could damage the material.
•
Align the motor carefully to avoid placing any unacceptable strain on the motor
shafts. Observe the permitted overhung and axial loads specified in the gear unit
catalog.
•
Do not jolt or hammer the shaft end.
•
Ensure sufficient clearance around the unit to allow for adequate cooling air sup-
ply. Warm outlet air of other units must not affect the cooling.
•
Balance components that were subsequently mounted to the shaft with a half key
(output shafts are balanced with a half key).
•
Use suitable cable glands for the supply leads (use reducing adapters if neces-
sary).
•
Seal the cable entry properly.
•
If the corrosion protection coating is damaged, restore the coating.
•
Check whether the degree of protection specified in the operating instructions and
on the nameplate is permitted in the ambient conditions on site.
22759468/EN – 11/2017