6
Startup
Additional information
Operating Instructions – CMP ELVCD
44
6.2.1
Required hardware and software
The following hardware and software must be present for startup:
Controller
Type
SD memory card
Program module
MOVI‑PLC
®
(program-
mable)
DH.21B (standard)
OMH21B-T0
MultiMotion Light
DH.41B (advanced)
OMH21B-T0
OMH41B-T2
MultiMotion
CCU (parameterizable)
DHF21B, DHR21B
(standard)
OMC21B-T0
Application Configurator
DHF41B, DHR41B (ad-
vanced)
OMC41B-T2
Also observe the following points in particular:
•
The SD memory card must be installed in the MOVI-PLC
®
controller.
•
The specified technology points correspond with the minimum requirement.
•
The MOVITOOLS
®
MotionStudio engineering software must be installed on the en-
gineering PC.
•
Version V180.100 or higher of the Application Configurator must be present.
•
Type DHE21B and DHE41B CCU controllers are not supported.
6.2.2
Application modules for CCU
Device type "ELVCD" must be used in the Application Configurator. The following
modules are available:
•
Universal module x PD
•
Universal module Technology
The description of the application modules can be found in the "Application Configur-
ator for CCU" manual.
6.3
Additional information
Further information can be found in the following documents:
•
Application Configurator
•
MultiMotion
•
MOVI-PLC
®
libraries
22759468/EN – 11/2017