10
Technical data
Brake
Operating Instructions – CMP ELVCD
102
10.6
Brake
10.6.1
BP brake
CMP50S, CMP50M with brake BP04
Nominal torque for slipping brake disk (relative speed between brake
disk and friction surface: 1 m/s) at 20 °C
M
2, 20 °C
3.1 Nm
Minimum static braking torque (holding torque) at 100 °C
M
4, 100 °C
1.0 Nm
Minimal averaged dynamic braking torque in case of emergency off at
100 °C
M
1m, 100 °C
1.2 Nm
Permitted braking work per braking operation
W
1
0.6 kJ
Permitted braking work per hour
W
2
7.2 kJ
Permitted total braking work (braking work until maintenance)
W
insp
1.0 × 10³ kJ
Power consumption of the coil
P
10.2 W
Brake response time
t
1
200 ms
Brake application time
t
2
75 ms
INFORMATION
The response and application times are guide values that were determined at maxi-
mum braking torque.
Possible response times of switching elements or controllers were not taken into ac-
count.
INFORMATION
If the permitted braking work per braking W
1
is exceeded during braking or if the per-
mitted total braking work W
insp
is reached, it can no longer be guaranteed that the
brake will be released.
In this case, the fault message 8977 or 8978 is signaled.
INFORMATION
For the current project planning standard for BK and BP brakes of the CMP50
ELVCD and the functional principle of the brakes, refer to the SEW‑EURODRIVE
"Synchronous Servomotors CMP40 – CMP112, CMPZ71 – CMPZ100" catalog.
If you have questions concerning the BP brake project planning, contact
SEW‑EURODRIVE support.
10.6.2
BK brake
CMP50S, CMP50M with brake BK02
Minimum static braking torque (holding torque) at 100 °C
M
4, 100 °C
2.4 Nm
Minimal averaged dynamic braking torque in case of emergency off at
100 °C
M
1m, 100 °C
1.9 Nm
Maximum dynamic braking torque in case of emergency off
M
1max
5.3 Nm
Permitted braking work per braking operation
W
1
0.175 kJ
22759468/EN – 11/2017