6
Startup
Parameter description
Operating Instructions – CMP ELVCD
65
Parameter 081.3
Signal: Hall sensor fault
This parameter indicates whether a fault has occurred at the encoder. Check the en-
coder configuration.
Parameter 081.4
Signal I
2
t motor fault (I
2
t at 100%)
The parameter indicates whether the calculated value I
2
t of the motor protection model
has reached 100%.
Parameter 081.5
Signal I
2
t controller fault (I
2
t at 100%)
The parameter indicates whether the calculated value I
2
t of the motor protection model
has reached 100%.
Parameter 081.6
Signal I
2
t fault (I
2
t at 80%)
The parameter indicates whether the calculated value I
2
t of the motor or controller pro-
tection model has reached 80%.
Parameter 081.7
Signal: Motor temperature 5 °C below maximum
The parameter indicates whether the motor temperature reached the threshold of 5 °C
below the permitted maximum.
Parameter 081.8
Signal: Output stage temperature 5 °C below maximum
The parameter indicates whether the inverter output stage temperature reached the
threshold of 5 °C below the permitted maximum.
Parameter 081.9
Signal: Lag error monitoring
The parameter indicates whether actual position is outside the permitted lag error win-
dow.
Parameter 082.0
Signal: Limit switch fault
The parameter indicates whether both limit switches are active at the same time.
Parameter 082.1
Signal: Timeout at rapid stop
The parameter indicates whether rapid stop ramp is configured incorrectly.
Parameter 082.2
Signal: Reference travel fault
22759468/EN – 11/2017