5
Electrical installation
Electrical connections
Operating Instructions – CMP ELVCD
37
5.8.6
X3: AK0H HIPERFACE
®
encoder connection
The following table shows information about this connection:
Function
AK0H HIPERFACE
®
encoder connection
Connection type
Cable with plug connector M23, 12-pin, female, 0°-coded
Connection image
9
1
2
7
6
5
11
12
3
4
8
10
No.
Name
Function
1
n.c.
Not connected
2
n.c.
Not connected
3
S1
Signal input,
4
S3
Signal input, cosine -
5
S2
Signal input, sine +
6
S4
Signal input, sine -
7
D -
RS485 connection -
8
D+
RS485 conn
9
PK/KTY+
Temperature sensor connection PK/KTY+
10
PK/KTY-
Temperature sensor connection PK/KTY-
11
GND
Reference potential
12
Us
Supply voltage
22759468/EN – 11/2017