5
Electrical installation
Electrical connections
Operating Instructions – CMP ELVCD
33
No.
Name
Function
6
DO01
Digital output DO01, parameterizable (Parameter de-
scription)
7
DI06
Digital input DI06, no function/transparent
8
+24 V
DC 24 V voltage supply for electronics and digital in-
puts/outputs
Module C
Connection image
C
B
A
1
2
No.
Name
Function
1
GND
Reference potential for DC link and electronics
2
+DC link
DC 48 V voltage supply for DC link
INFORMATION
In order to enable the output stage, pin A5 and pin B8 must be jumpered, or DC 24 V
must be applied to pin A5.
In order to switch the digital inputs with the DC 24 V electronic supply, pin B4 and
pin C1 must be jumpered. In order to switch the digital inputs with the DC 24 V ex-
ternal voltage, pin B4 must be jumpered with the reference potential of the external
voltage.
22759468/EN – 11/2017