7
Operation
Parameter tree
Operating Instructions – CMP ELVCD
77
[5] [Reset] button
DANGER!
Automatic start-up of the ELVCD drive after acknowledging an active
fault. Severe or fatal injuries.
Ensure that an automatic start-up is not a danger to people and equipment.
All active faults with the exception of certain STO fault messages are acknowledged
by pressing this button. These can only be acknowledged by restarting the drive. If the
enable and setpoints ≠ 0 are still present after acknowledging the fault, the drive at-
tempts to follow the setpoint.
[6] "Error" status display
Red: There is a fault in the inverter. To display the fault code and other information,
move the mouse pointer over the fault display. An overview of the fault codes can be
found in section "Fault list" (→
85).
Gray: There is no fault.
[7] [Back] button
The view switches back to the overview window of the ELVCDDriveManager.
If you have changed a parameter, you have the choice between permanent and tem-
porary retention of the changes:
• Click on the [Yes] button to stop the relevant axis of the ELVCD drive and back up
the parameters in the ELVCD inverter.
• Click on the [No] button to discard the changes. The next time the ELVCD drive is
started, the parameters backed up in the ELVCD inverter will be loaded.
[8] "FB-Error" status display
Red: Fault in the processing of a program module. To display the fault code and other
information, move the mouse pointer over the fault display. An overview of the fault
codes can be found in section "Fault list" (→
Gray: There is no fault.
[9] "IP address" display
Display of IP address of controller in MOVITOOLS
®
MotionStudio.
[10] "Parameter" choice box
Choice boxes have a white background. You can change the value of the parameter.
[11] "Parameter" display field
Display fields have a gray background. You cannot change the value of the para-
meter.
22759468/EN – 11/2017