6
Startup
Parameter description
Operating Instructions – CMP ELVCD
60
The parameter indicates the temperature of the inverter output stage in °C.
Parameter 011.0
Inverter status
The following inverter statuses are possible:
•
Not ready for operation
•
Switch-on inhibited
•
Not enabled
•
On
•
Enabled
•
Rapid stop active
•
Fault
•
STO active
Parameter 012.0
Fault status
The parameter indicates the fault code and the fault designation.
Parameter 013.0
Warning status
The parameter indicates whether a warning is active.
Parameter 020.0
Normal state
The parameter indicates whether the drive is in a normal operating state.
Parameter 021.0
STO safe state reached
The parameter indicates whether the STO safe state has been reached.
Parameter 022.0
Safety circuit fault
This parameter indicates whether a fault has occurred in the safety circuit.
Parameter 023.0
STO 1 feedback (PWM power driver off)
The parameter indicates that the power driver is switched off.
Parameter 024.0
STO 2 feedback (driver supply off)
The parameter indicates that the driver supply is switched off.
22759468/EN – 11/2017