6
Startup
Parameter list
Operating Instructions – CMP ELVCD
55
No.
Index
dec.
Sub-
index
dec.
Name
MOVITOOLS
®
MotionStudio (range /
factory setting)
CANopen scaling or
bit assignment
3__
Motor parameters
30_
Limits
302.0 33
0
Maximum speed
2 –
3300
– 32768 min
-1
1 Digit = 2
-12
min
-1
303.0 29
0
Maximum current
0.11 –
32
A
1 digit = 1/92682 A
305.0 30
0
I
2
t-time constant
400 –
10000
ms
1 Digit = 0.0001 ms
32_
Brake function
325.0 51
0
Brake release time
0 –
200
6553.5 ms
1 Digit = 0.0001 ms
325.1 52
0
Brake application time
0 –
75
6553.5 ms
1 Digit = 0.0001 ms
35_
Direction of motor rotation
350.0 48
0
Direction of rotation reversal
0: No (direction of rota-
tion not reversed)
1: Yes (direction of rota-
tion is reversed)
Bit 10
No.
Index
dec.
Sub-
index
dec.
Name
MOVITOOLS
®
MotionStudio (range /
factory setting)
CANopen scaling or
bit assignment
6__
Terminal assignment
60_
Digital inputs
600.0 149
0
Activate digital output DI00
0: No
1: Yes
Bit 0
601.0 149
0
Activate digital output DI01
0: No
1: Yes
Bit 1
602.0 149
0
Activate digital output DI02
0: No
1: Yes
Bit 2
603.0 149
0
Activate digital output DI03
0: No
1: Yes
Bit 3
61_
Limit switches
610.0 49
0
Limit switch option lock direction
of rotation
0: Yes (direction of rota-
tion locked)
1: No (direction of rota-
tion not locked)
Bit 4
610.1 148
0
Limit switch type
0: NC contact
1: NO contact
Bit 2
62_
Digital outputs
22759468/EN – 11/2017