2 PRINCIPLE OF OPERATION
The VB330 module is equipped with two SFP+ optical ports and one RJ45 Ethernet port. The user
selects which transport stream signal input to be used by the monitoring engine. Management of the
probe is conducted via the Ethernet management port or alternatively in-band via the video/data ports.
VB330 Module
Monitoring Engine
SFP+ A (optional port)
SFP+ B main port
Ethernet Management
SNMP Traps
Figure 2.1: The VB330 Module – Principle of Operation
A simplified diagram of the alarm handling mechanisms of the 10G Probe is shown in figure 2.2. The
input signals are continuously analyzed, and measured data are checked against user defined threshold
values. If the data do not comply with the threshold values alarms will be generated. The overall alarm
settings further make it possible to enable and disable alarms, thus defining which alarms should be
reported in the 10G Probe alarm list and sent as SNMP traps to an external management system.
12
VB3xx 10G Probe User’s Manual version 5.3