E Appendix: Software Upload
The process of performing a software upload to the probe involves the following steps:
1. Obtain the software image.
2. Export and save the probe configuration.
3. Delete any existing probe stream recordings.
4. Transfer the image to the probe using the software upload functionality in the
view or by using ftp, and save the image to flash.
5. Wait while the software is being saved.
6. Verify the new image.
E.1
Obtain the software image
The image will have a
.tea
extension.
The version number, build date and possibly hardware version is usually also part of the file name.
E.2
Export and save the probe configuration
Software upgrade should not alter the probe configuration, however for safety is is a good idea to export
the probe configuration (from the
view) and save it to a file. Please refer to
E.3
Delete any existing probe stream recordings
If any stream recordings is stored on the probe, this may prevent software upgrade, as there might not be
enough internal disk space available for the software image upload to be possible. Therefore delete any
recordings prior to software upload – this is done in the
view.
198
VB3xx 10G Probe User’s Manual version 5.3
Содержание VB330
Страница 1: ...VB3xx 10G Probes Applies to software release v5 3 Form 8046E February 2017...
Страница 7: ...F Appendix Restoring probe factory defaults 203 VB3xx 10G Probe User s Manual version 5 3 7...
Страница 29: ...VB3xx 10G Probe User s Manual version 5 3 29...
Страница 30: ...6 THE 10G PROBE GRAPHICAL USER INTERFACE 30 VB3xx 10G Probe User s Manual version 5 3...
Страница 101: ...VB3xx 10G Probe User s Manual version 5 3 101...
Страница 149: ...The PID threshold template has the following settings VB3xx 10G Probe User s Manual version 5 3 149...