The ETR threshold template has the following settings:
ETR Thresholds — Parameters:
Name:
A text field with the name of the ETR threshold template
Description:
Text field that should contain a meaningful description of the threshold
Analysing Mode:
The mode of table analysis. DVB or ATSC may be selected.
Error timeout (s):
The number of seconds after an error has occurred before the alarm is cleared
as long as no new alarms are generated. For all table related alarms the
actual alarm timeout which is used is the sum of the Error timeout parameter
and the maximum table repetition period. E.g. the TDT with table repetition set
to 30 seconds will have an effective error timeout of 40 seconds. This avoids
toggling of alarms for tables that are sent infrequently. Default value: 10 s
138
VB3xx 10G Probe User’s Manual version 5.3