TTL changed:
The Time-To-Live field is changing
Default: Enabled,
severity Error
TOS changed:
The Type-Of-Service field is chang-
ing
Default: Enabled,
severity Error
Multiple mcast sources:
There
are
multiple
multicast
sources
Default: Enabled,
severity Error
Mcast source changed:
The multicast source changed to
one of the valid multicast sources
specified by the operator.
Default: Enabled,
severity Error
Bitrate overflow:
The net stream bitrate exceeds the
maximum bitrate Ethernet threshold
value specified by the operator.
Default: Enabled,
severity Error
Bitrate underflow:
The net stream bitrate goes be-
low the minimum bitrate Ethernet
threshold value specified by the op-
erator.
Default: Enabled,
severity Error
FSM alarms
Full service monitoring:
No reply was obtained within time-
out period for the configured FSM
service
Default: Enabled,
severity Major
ETR (ETR 290) alarms
TS Sync:
No TS Sync (no signal)
Default: Enabled,
severity Major
Sync byte:
Sync byte error, sync byte not 0x47
Default: Enabled,
severity Major
PAT:
Program Association Table error
Default: Enabled,
severity Major
Continuity:
Continuity counter error
Default: Enabled,
severity Major
PMT:
Program Map Table error
Default: Enabled,
severity Major
PID:
PID is missing
Default: Enabled,
severity Major
Transport:
Transport stream error indicator is
set
Default: Enabled,
severity Major
VB3xx 10G Probe User’s Manual version 5.3
43
Содержание VB330
Страница 1: ...VB3xx 10G Probes Applies to software release v5 3 Form 8046E February 2017...
Страница 7: ...F Appendix Restoring probe factory defaults 203 VB3xx 10G Probe User s Manual version 5 3 7...
Страница 29: ...VB3xx 10G Probe User s Manual version 5 3 29...
Страница 30: ...6 THE 10G PROBE GRAPHICAL USER INTERFACE 30 VB3xx 10G Probe User s Manual version 5 3...
Страница 101: ...VB3xx 10G Probe User s Manual version 5 3 101...
Страница 149: ...The PID threshold template has the following settings VB3xx 10G Probe User s Manual version 5 3 149...