5 QUICK SETUP GUIDE
This quick setup guide is intended to provide a step-by-step explanation of how to setup a probe once
the initial setup has been performed (as described in chapter 4).
More detailed instructions are found in chapter 6 of this manual.
The Return Data Path and Full Service Monitoring features are not covered by this quick setup guide.
5.1
Basic Setup
1. Set appropriate parameters in the
and
Setup — Ethernet
views.
2. Enabling Time synchronization is strongly recommended, this can be done in
If no time reference for automatic time locking is available set the time manually in the
view.
3. If access control is required, define a password in the
view.
Note:
it is important to read the instructions in the associated section of this manual, see chap-
5.2
Input Signal Definitions
5.2.1
Multicasts
1. Define multicasts, either by using the multicast detect feature (
) or by defining
multicasts manually (
Note:
Often upstream equipment will not transmit multicasts unless join messages have been
received, and in this case it will usually not be possible to detect multicasts automatically. Select
predefined threshold templates that seem appropriate for the signal. Note that the sequence of
the multicast definitions will be reflected in monitoring, so order the multicasts correctly if required.
Also note that ETR 290 monitoring for Ethernet streams is disabled by default, so if this is required,
it will have to be enabled by the user (on a per-stream basis).
26
VB3xx 10G Probe User’s Manual version 5.3
Содержание VB330
Страница 1: ...VB3xx 10G Probes Applies to software release v5 3 Form 8046E February 2017...
Страница 7: ...F Appendix Restoring probe factory defaults 203 VB3xx 10G Probe User s Manual version 5 3 7...
Страница 29: ...VB3xx 10G Probe User s Manual version 5 3 29...
Страница 30: ...6 THE 10G PROBE GRAPHICAL USER INTERFACE 30 VB3xx 10G Probe User s Manual version 5 3...
Страница 101: ...VB3xx 10G Probe User s Manual version 5 3 101...
Страница 149: ...The PID threshold template has the following settings VB3xx 10G Probe User s Manual version 5 3 149...