There are two different ways of creating a Gold TS reference template:
•
Creating a template for the currently tuned stream on a specific input
•
Creating a template for all streams on a specific input (or all inputs)
When creating a template for a specific stream the table set is saved immediately. It is therefore
recommended that the ETR tuning is locked to this stream to avoid the round-robin operation from tuning
to a new frequency just before the table set is stored. It can take 30 seconds after tuning to receive all
tables.
When creating templates for all streams on an input this is done as a part of the round robin cycle at the
end if the tuning period. It can then take a while for all thresholds to be generated (or updated) depending
on the number of streams on that input.
When the reference template have been created it is automatically associated with the stream for which it
was generated.
The operation of the Gold TS reference thresholds are controlled by the ETR threshold template
associated with the stream. No settings are changed here when creating the reference templates so this
needs to be done manually by going to
If needed a new template can be created and associated with the stream(s). Or the existing template(s)
can be changed.
VB3xx 10G Probe User’s Manual version 5.3
155
Содержание VB330
Страница 1: ...VB3xx 10G Probes Applies to software release v5 3 Form 8046E February 2017...
Страница 7: ...F Appendix Restoring probe factory defaults 203 VB3xx 10G Probe User s Manual version 5 3 7...
Страница 29: ...VB3xx 10G Probe User s Manual version 5 3 29...
Страница 30: ...6 THE 10G PROBE GRAPHICAL USER INTERFACE 30 VB3xx 10G Probe User s Manual version 5 3...
Страница 101: ...VB3xx 10G Probe User s Manual version 5 3 101...
Страница 149: ...The PID threshold template has the following settings VB3xx 10G Probe User s Manual version 5 3 149...