![Sencore VB330 Скачать руководство пользователя страница 110](http://html1.mh-extra.com/html/sencore/vb330/vb330_user-manual_1239233110.webp)
Buffer use %:
Current buffer utilization. At 100% the
Dropped packets
will start counting.
Disk free:
Remaining disk size.
Capture:
The recorded capture. May be invalid if recording is still in progress.
Start recording:
Click to start a new recording. This will clear the current rec.pcap file.
Stop recording:
Click to stop the current recording.
Sort recorded frames
on packet time:
At high bitrates, some Ethernet frames may be recorded out of order as
a result of the multi-core architecture. Click to sort frames in recording
according to time-stamp.
6.9
ETR 290 (Option)
The ETR 290 tab and all sub-views will only be present in the user interface provided that the probe is
licensed with the ETR 290 option.
The ETR 290 views show information as reported by the ETSI TR 101 290 monitoring engines.
If ETR 290 analysis has been configured for multiple Ethernet streams to be monitored by a particular
Ethernet ETR engine (refer to
), they will be analyzed in a round-robin
fashion by the engine. A maximum of 2000 Ethernet streams may be analyzed in total.
The number of ETR 290 analysis engines depends on the license. The SW currently support up to 200
engines which are added in increments of 50. More engines make it possible to reduce the analysis
round-trip time or allowing simultaneous full-time ETR analysis of many multicasts. The ETR 290 analysis
engines operate in parallel.
It is possible to hide disabled inputs from being displayed in the various
ETR 290
sub-views. This setting
is found in the
view.
110
VB3xx 10G Probe User’s Manual version 5.3
Содержание VB330
Страница 1: ...VB3xx 10G Probes Applies to software release v5 3 Form 8046E February 2017...
Страница 7: ...F Appendix Restoring probe factory defaults 203 VB3xx 10G Probe User s Manual version 5 3 7...
Страница 29: ...VB3xx 10G Probe User s Manual version 5 3 29...
Страница 30: ...6 THE 10G PROBE GRAPHICAL USER INTERFACE 30 VB3xx 10G Probe User s Manual version 5 3...
Страница 101: ...VB3xx 10G Probe User s Manual version 5 3 101...
Страница 149: ...The PID threshold template has the following settings VB3xx 10G Probe User s Manual version 5 3 149...