Enable the
Show additional measurements
checkbox to view additional measurements that are done
but which are ignored when determining the alarm status. These will appear with a ‘half-bulb’ icon
indicating that the check is disabled whilst also showing the status of this element. As an example this
can be used to view the BAT section repetition interval and section gap, or to view a list of PIDs with CC
errors including the PIDs for which this check has been manually disabled.
Click a PID in a PID list to view PID details. Similarly you can click on a service to view service details.
If the
Clear status
button is clicked the error counts are reset and the ETR 290 analysis restarts.
The details of the individual ETR 290 measurements are described in a separate document called
Sencore VideoBRIDGE ETR 290 Details — Extended ETSI TR 101 290 Testing
.
Clicking the
Show alarm graph
button opens the Alarm graph pop-up view.
The alarm graph shows the transport stream ETR alarm status over time in the form of a status timeline.
The timeline bar shows the stream status for a time span of 90 minutes, 8 hours or 24 hours as selected
by clicking the time selection buttons below the timelines. The stream bar reveals any alarm that has been
present during the selected time period. The bar color is either green for OK or colored in accordance
with the alarm severity if an alarm has occurred. Refer to section 6.2.2 for a description of the alarm
VB3xx 10G Probe User’s Manual version 5.3
113
Содержание VB330
Страница 1: ...VB3xx 10G Probes Applies to software release v5 3 Form 8046E February 2017...
Страница 7: ...F Appendix Restoring probe factory defaults 203 VB3xx 10G Probe User s Manual version 5 3 7...
Страница 29: ...VB3xx 10G Probe User s Manual version 5 3 29...
Страница 30: ...6 THE 10G PROBE GRAPHICAL USER INTERFACE 30 VB3xx 10G Probe User s Manual version 5 3...
Страница 101: ...VB3xx 10G Probe User s Manual version 5 3 101...
Страница 149: ...The PID threshold template has the following settings VB3xx 10G Probe User s Manual version 5 3 149...