045
5
Opening of the Door Safety Contacts during the passing of the car at landing 01
046
5
Opening of the Door Safety Contacts during the passing of the car at landing 02
047
5
Opening of the Door Safety Contacts during the passing of the car at landing 03
048
5
Opening of the Door Safety Contacts during the passing of the car at landing 04
049
5
Opening of the Door Safety Contacts during the passing of the car at landing 05
050
5
Opening of the Door Safety Contacts during the passing of the car at landing 06
051
5
Opening of the Door Safety Contacts during the passing of the car at landing 07
052
5
Opening of the Door Safety Contacts during the passing of the car at landing 08
053
5
Opening of the Door Safety Contacts during the passing of the car at landing 09
054
5
Opening of the Door Safety Contacts during the passing of the car at landing 10
055
5
Opening of the Door Safety Contacts during the passing of the car at landing 11
056
5
Opening of the Door Safety Contacts during the passing of the car at landing 12
069
5
Opening of the Door Safety Contacts during the re-phasing operation
076
5
The door opening time of the operator 1 is too long. The time has overcome the value set at the
parameter 3.8.5
077
078
5
The door opening time of the operator 1 is too long. The time has overcome the value set at the
parameter 3.8.6
079
2
The contact SED is closed with car at the top floor. Input X9.4 with tension
080
1
The contacts SED and SEB are open with the car at the bottom floor
081
4
The outputs RUN and READY of NGVA3 have been in the same sate for more than 1 s
088
4
An unintendent car movement has occurred. The car is out of the un-locking zone
090
3
The oil temperature is too high. . Thermal sensor is connected to the clamps T01-T02
091
4
The Oil Pressure is too low. It is under the minimum pressure
092
4
The Oil Pressure is too high. It is over the maximum pressure
095
3
General alarm related to the activation of the programmed input with function 28
096
1
General alarm related to the activation of the programmed input with function 48
097 5 No
departure
101
5
No recognition of the IS signal during the stopping at the 2° floor in up direction
102
5
No recognition of the IS signal during the stopping at the 3° floor in up direction
103
5
No recognition of the IS signal during the stopping at the 4° floor in up direction
104
5
No recognition of the IS signal during the stopping at the 5° floor in up direction
105
5
No recognition of the IS signal during the stopping at the 6° floor in up direction
106
5
No recognition of the IS signal during the stopping at the 7° floor in up direction
107
5
No recognition of the IS signal during the stopping at the 8° floor in up direction
108
5
No recognition of the IS signal during the stopping at the 9° floor in up direction
109
5
No recognition of the IS signal during the stopping at the 10° floor in up direction
110
5
No recognition of the IS signal during the stopping at the 11° floor in up direction
111
5
No recognition of the IS signal during the stopping at the 12° floor in up direction