INSTALLATION AND USE
STK3-GMV10 Control panel and Pre-wiring
For Hydraulic Elevators
MSTK3-GB
Rev.04
05/02/12
© Sea Systems S.r.l.
Page 18 of 81
B.8.3. S
HAFT
W
ITHOUT
E
NCODER
S
ENSORS
M
OUNTING AND
C
ONNECTIONS
Description
The shaft houses the following sensors:
•
Two timing devices (SRD, SRS) for the end floor speed change, toggle contacts
•
A monostable contact (SIS) for stopping and speed changes when rising
•
A monostable contact (SID) for stopping and speed changes during decent
•
Two monostable contacts (SIZ1, SIZ2) for the safety circuit control
B) Installation
1.
Mount the two bracketed shaft impulse generator kits (p/n PIV01 and PIV02) on the roof of
the cab as shown in the schematic diagram 2.8.3.1 shown below.
Dia. B.8.3.1- Sensor Mounting Schematic Diagram For Shaft Without Encoder