![SEA STK3-GMV10 Скачать руководство пользователя страница 44](http://html.mh-extra.com/html/sea/stk3-gmv10/stk3-gmv10_manual-for-installation-and-use_1220677044.webp)
SEA SYSTEMS
INSTALLATION AND USE
STK3-GMV10 Control panel and Pre-wiring
For Hydraulic Elevators
MSTK3-GB
Rev.04
05/02/12
© Sea Systems S.r.l.
Page 44 of 81
3.1 Settings \ Valve NGV
This menu is displayed if the parameter 2.3 is set like NGV01
.1 Soft Stop
x.x s
Delay time to activate and deactivate VMP valve (Soft Stop) (range
0.0…3.0s)
3.1 Settings \ Valve NGV-DLV-A3
This menu is displayed if the parameter 2.3 is set like NGV01-DLV-A3
.1 Soft Stop
x.x s
Delay time to activate and deactivate VMP valve (Soft Stop) (range
0.0…3.0s)
Ã
Ä
.2 DLV-VMD Test
xx s
Activation Time to check the valves DLV and VMD during the
monitoring according to Amendment A3 (range 3…10 s)
3.1 Settings \ Valve NGV-A3
This menu is displayed if the parameter 2.3 is set like NGV01-A3
.1 Run <-> Ready
xx s
Delay time to detect the failure of NGVA3 (range 2…5 s)