SEA SYSTEMS
INSTALLATION AND USE
STK3-GMV10 Control panel and Pre-wiring
For Hydraulic Elevators
MSTK3-GB
Rev.04
05/02/12
© Sea Systems S.r.l.
Page 28 of 81
D)
GEV valve Self-Tuning
When first installed and/or when a valve part is replaced, or if the STK3-EV01 board is replaced,
the valve must be calibrated using the self-tuning maneuver in menu 4.3.2
Service\Calibration\GEV Self-Tuning
.
This maneuver can be performed in two plant operation modes:
•
4.1.1
Service\Operation\Mode : Installation
In this case, commutate the shunt on the installation button panel, close the oil shutter,
bridge XG1-XG2, and execute the command in menu 4.3.2
Service\Calibration\GEV
Self-Tuning
•
4.1.1
Service\Operation\Mode : Normal
In this case, make certain that the safeties are closed, close the oil shutter, bridge XG1-
XG2, and execute the command in menu 4.3.2
Service\Calibration\GEV Self-Tuning
In either case, a lifting movement will be controlled for approx. 40 seconds during which the valve
is calibrated.
At the end of the operation, save the parameters (Menu 5 Save Data), remove the XG1-XG2
bridge, and open the shutter.