1.9 Diagnostics\Inputs-Outputs
RD RS ID IS CS M
0 0 0 0 0 0
Ã
Ä
Displays the status of the floor indicators and safety circuit
•
RD, RS
Ascent and Descent re-phase
•
ID, IS
Stop/Change speed impulse
When Shaft Encoder is selected, they display that equivalent
state of the stop contacts on the contact shaft.
•
CS
, status of the door safety circuit
•
M
, status of the IM impulse, used only with encoder shafts
0= Open Contact, 1= Closed Contact
H10 8 7 5 2E 2 1
0 0 0 0 0 0 0
Ã
Ä
Displays the status of the safety chain indicators to the board terminals:
10,8,7,5,2E,2,1
0= Open Contact, 1= Closed Contact
IP.. 987654321
000000000
Ã
Ä
Displays the status of the input signals
IP9…IP1
.
0= Open Contact, 1= Closed Contact
HC.. 87654321
00000000
Ã
Ä
Displays the status of the input signals
8
(X9.3),
7
(X9.4),
6
(HC6),
5
(HC5),
4
(HC4),
3
(HC3),
2
(HC2),
1
(HC1)
0= Open Contact, 1= Closed Contact
FA1 FC1 FA2 FC2
0 0 0 0
Ã
Ä
Displays the status of the door limit switch input signals:
FA1,
FC1, FA2, and FC2
.
0= Open Contact, 1= Closed Contact
CM1 CM2 FT1 FT2
0 0 0 0
Ã
Ä
Displays the status of the input signals relative to the safety device and
door photocell:
CM1, CM2, FT1, and FT2
.
0= Open Contact, 1= Closed Contact
MR PA1 PA2 PCP
0 0 0 0
Ã
Ä
Displays the status of the Cabin Button Panel input signals
MR
Reserved Operation Key
PA1
, Open Door 1 Button
PA2
, Open Door 2 Button
PCP
; Close Door Button
0= Open Contact, 1= Closed Contact
E.. 210987654321
000000000000
Ã
Ä
Displays the status of the floor call input signals
E12…E1
.
0= Open Contact, 1= Closed Contact
ES. 432109876543
000000000000
Ã
Ä
Displays the status of the floor call input signals
E24…E13
, Call
Expansion