SEA SYSTEMS
INSTALLATION AND USE
STK3-GMV10 Control panel and Pre-wiring
For Hydraulic Elevators
MSTK3-GB
Rev.04
05/02/12
© Sea Systems S.r.l.
Page 30 of 81
B.10) Isolation Test
Prior to performing the Isolation tests shown in the table below, perform the following
steps:
1
Stop the cab off floor
2
Remove power to the QFM motor power and QL light
3
Disconnect and insulate the earth wire from the power supply device AL01
4
Disconnect the pressure transducer
5
Disconnect the telephone line to the dialer.
FROM
TO
Engine
Power,
Motors
R,S,T,
U,V,W,
U1,V1,W1
U2,V2,W2
Safeties
1..10
Cabin
lights
L1,L,N
Continuous
door motor
OP02, OP03,
OP05, OP06,
OP07, OP08
Indicators
OC, FS
Ground
U
U U U
U
Engine Power,
Motors
R,S,T, U,V,W,
U1,V1,W1
U2,V2,W2
NO
U U U
U
Safeties
1..10
U
NO
U
NO
U
Alarms
+AL, -AL-, AL
U
NO
U
NO
U
Cabin lights
L1, L, N
U
U
NO
U
U
Indicators
OC, FS
U
U
U U
NO
Safety Circuit
ID1, ID2, IS1,
IS2, IZ
U
NO
U
NO
U
U
= Perform isolation test.