3
Date Code 20060320
Instruction Manual
SEL-311C Relay
SEL-311C Relay Command Summary
Access Level B
Commands
Access Level B commands primarily allow the user to operate output contacts. All Access Level 1
commands can also be executed from Access Level B. The screen prompt is: ==>
BRE
n
Enter
BRE W
to preload breaker wear. Enter
BRE R
to reset breaker monitor data.
CLO
Close the circuit breaker. See
for more information concerning the
CLO
command.
GRO
n
Change active group to Group
n
.
OPE
Open the circuit breaker. See the text following
and the discussion on
for
more information concerning the
OPE
command.
PUL
n k
Pulse output contact
n
(
OUT101
–
OUT107
,
ALARM
,
OUT201
–
OUT212
) for
k
(1–30) seconds. Parameter
n
must be
specified;
k
defaults to 1 if not specified.
Access Level 2
Commands
The Access Level 2 commands allow unlimited access to relay settings, parameters, and output
contacts. All Access Level 1 and Access Level B commands are available from Access Level 2. The
screen prompt is: =>>
CON
n
Control Remote Bit RB
n
(Remote Bit
n
;
n
= 1 through 8). Execute
CON
n
and the relay responds:
CONTROL
RBn
. Then reply with one of the following:
SRB
n
set Remote Bit
n
(assert RB
n
).
CRB
n
clear Remote Bit
n
(deassert RB
n
).
PRB
n
pulse Remote Bit
n
(assert RB
n
for 1/4 cycle).
COP
m n
Copy relay and logic settings from Group
m
to Group
n
.
DNP [type]
Set DNP map.
L_D
Load new firmware.
LOO
Set M
IRRORED
B
ITS
port to loop back.
PAS
Show existing Access Level 1, B, and 2 passwords.
PAS 1
xxxxxx
Change Access Level 1 password to
xxxxxx
.
PAS B
xxxxxx
Change Access Level B password to
xxxxxx
.
PAS 2
xxxxxx
Change Access Level 2 password to
xxxxxx
.
SET
n
Change relay settings (overcurrent, reclosing, timers, etc.) for Group
n
.
SET L
n
Change SEL
OGIC
control equation settings for Group
n
.
SET G
Change global settings.
SET P
n
Change Port
n
settings.
SET R
Change Sequential Events Recorder (SER) settings.
SET T
Change text label settings.
STA C
Resets self-test warnings/failures and reboots relay.
VER
Displays version and configuration information.
Содержание SEL-311C
Страница 1: ...20060320 SEL 311C Relay Protection and Automation System Instruction Manual PM311C 01 NB ...
Страница 22: ...This page intentionally left blank ...
Страница 42: ...This page intentionally left blank ...
Страница 68: ...This page intentionally left blank ...
Страница 128: ...This page intentionally left blank ...
Страница 294: ...This page intentionally left blank ...
Страница 330: ...This page intentionally left blank ...
Страница 402: ...This page intentionally left blank ...
Страница 406: ...This page intentionally left blank ...
Страница 454: ...This page intentionally left blank ...
Страница 574: ...This page intentionally left blank ...
Страница 592: ...This page intentionally left blank ...
Страница 616: ...This page intentionally left blank ...
Страница 648: ...This page intentionally left blank ...
Страница 652: ...This page intentionally left blank ...
Страница 678: ...This page intentionally left blank ...
Страница 682: ...This page intentionally left blank ...
Страница 722: ...This page intentionally left blank ...
Страница 724: ...This page intentionally left blank ...
Страница 732: ...This page intentionally left blank ...
Страница 748: ...This page intentionally left blank ...