14.14
SEL-311C Relay
Instruction Manual
Date Code 20060320
Application Settings for SEL-221 Series Relays
SEL-221G-5 to SEL-311C Settings Conversion Guide
Convert SEL-221G-5
Output Mask Logic
Settings to SEL
OGIC
Control Equations
See
Programmable Output Contact Mask Settings
in
Section 5: Applications
in the SEL
-221G-5 Instruction Manual
for a description of output masks. In
the SEL-311C, output masks are replaced by SEL
OGIC
control equations as
ORDER Q
V
I
= 32QE
= 32VE
= 32IE
Directional Control for Ground
Distance and Residual Ground
Overcurrent Elements on
page 4.9
Section 2—Directional Elements
79OI1
= 79OI1
Section 6: Close and Reclose
Logic
Section 5—Reclose Logic
79OI2
= 79OI2
79OI3
= 79OI3
79RSD
None (SEL-221G setting 79RS serves a
slightly different purpose.)
Reclosing Relay Timer Settings
on page 6.14
Section 6—79RS Timer Eliminates
Standing Close
79RSLD
None
52AEND
= 52BT (Pickup
Switch-Onto-Fault Trip Logic
on page 5.7
Section 5—High Set Phase Over-
current Setting (50H)
SOTFD
= 52BT (Dropout)
Z3XPU
None (221G-5 fixed at 2 cycles)
Directional Comparison Block-
ing Logic on page 5.25
Section 5—Zone 2 Short Phase
Time Delay; Zone 2 Short Residual
Overcurrent Time Delay
Z3XD
None (221G-5 fixed at 5 cycles
BTXD
None (221G-5 fixed at 0.5 cycles)
21SD
= Z2SP
67SD
= Z2SG
TDURD
= TDUR
Section 5—Trip Duration Timer
(TDUR)
SV1PU
= 50MFD
a
SEL-311C phase-to-phase fault detector settings 50PP1, 50PP2, and 50PP3 are set to 0.1 •I
NOM
and are hidden. This corresponds to
SEL-221G-5 setting 50L.
b
Curve U1 in the SEL-311C is slightly different from curve 1 in the SEL-221G-5. Time dial adjustments may be necessary.
c
The SEL-221G-5 uses a circular out-of-step characteristic. The SEL-311C uses a quadrilateral out-of-step characteristic.
Table 14.5
SEL-311C Settings Calculated From SEL-221G-5 Settings
(Sheet 3 of 3)
SEL-311C
Setting
a
Calculated From SEL-221G-5 Settings
SEL-311C Instruction
Manual Section
SEL-221G-5 Instruction
Manual Section
Table 14.6
SEL-311C SEL
OGIC
Control Equation Equivalent to Each
SEL-221G-5 Mask Logic Setting
SEL-221G-5 Settings Mask
SEL-311C SEL
OGIC
Control Equations
MTU
TR
MPT
SV2 (DTT)
MTB
TRCOMM
MTO
TRSOTF
MA1
OUT104
MA2
OUT105
MA3
OUT106
MA4
OUT107
MRI
79RI
MRC
79DTL
Содержание SEL-311C
Страница 1: ...20060320 SEL 311C Relay Protection and Automation System Instruction Manual PM311C 01 NB ...
Страница 22: ...This page intentionally left blank ...
Страница 42: ...This page intentionally left blank ...
Страница 68: ...This page intentionally left blank ...
Страница 128: ...This page intentionally left blank ...
Страница 294: ...This page intentionally left blank ...
Страница 330: ...This page intentionally left blank ...
Страница 402: ...This page intentionally left blank ...
Страница 406: ...This page intentionally left blank ...
Страница 454: ...This page intentionally left blank ...
Страница 574: ...This page intentionally left blank ...
Страница 592: ...This page intentionally left blank ...
Страница 616: ...This page intentionally left blank ...
Страница 648: ...This page intentionally left blank ...
Страница 652: ...This page intentionally left blank ...
Страница 678: ...This page intentionally left blank ...
Страница 682: ...This page intentionally left blank ...
Страница 722: ...This page intentionally left blank ...
Страница 724: ...This page intentionally left blank ...
Страница 732: ...This page intentionally left blank ...
Страница 748: ...This page intentionally left blank ...