System Overview
Operating Manual ProNumeric XCI 600 Version 07/16
15
3.5
Integrating the XCI 600 in an industrial infrastructure
Figure 3: Integrating the XCI 600 in an
industrial infrastructure
(01):
Corporate network
(02):
2 x Gigabit Ethernet
(03):
Top view XCI 600
(04):
External monitor, mouse and keyboard
(05):
Bottom view XCI 600
(06):
2 x real-time Ethernet
(07):
Field-bus network, Add-on card
(08):
Real-time Ethernet sensor / Actor
gateway
(09):
Field-bus sensor / Actor gateway
(E.g. via optional CAN card)
(10):
Sensor / Actor
(11):
Sensor / Actor
3.6
Keyboard and mouse
Keyboard and mouse can be connected to the USB interfaces.
Operation without a keyboard, mouse and monitor is generally possible.
3.7
SSD
An SSD is available to save the operating systems and applications.
Note
To minimize write accesses to the SSD, Windows Embedded is used
and the EWF (Enhanced Write Filter) is set by default.
3.8
Retentive memory
128 KB NVRAM are available on the XCI 600. In order not to slow down the
processor unnecessarily, accesses to the NVRAM do not take place directly,
but are buffered via the random access memory (SDRAM).
A special background process takes over synchronization between RAM and
NVRAM.