Commissioning
Operating Manual ProNumeric XCI 600 Version 07/16
25
4.3.4
Customizing the XCx-TCP/IP settings
Important!
First clarify the adaptation of the IP addresses with your network
administrator for your in-house network.
To make the TCP/IP settings for the network card, use the Schleicher X-
Manager (see: section 13.1).
4.3.5
Communication for programming with MULTIPROG
To use MULTIPROG for programming on an external PC, set up a network
route on the respective PC.
To do so, press <R> simultaneously.
Type in <
cmd
> and confirm by pressing <
OK
>.
Figure 10: Run window
Entering an exemplary IP scheme:
route –p add 192.168.212.0 mask 255.255.255.0
10.208.3.212
(-p for permanent), confirm with
<Enter>.
Important!
For the corresponding IP address, refer to the Schleicher X-Manager
(see: section 13.1) on the XCI 600.
You will require administrator rights to set up the route on the external
PC.
Figure 11:
Setting up the network
route for programming
with MULTIPROG