Other Operating Software
Operating Manual ProNumeric XCI 600 Version 07/16
83
13
Other Operating Software
13.1
Schleicher X-Manager
The Schleicher X-Manager provides the means for configuring important
parameters and settings for operating the controller:
13.1.1
"IP Configuration"
This function can be used to adapt the network settings required for
operation to the characteristics of the local network (home network).
The real time operating system VxWorks as well as Windows embedded
operate “simultaneously” on the XCI controller. Both operating systems
communicate with each other via a shared memory and a virtual network.
So-called "virtual network adapters" ("RTOS Virtual Network") are provided
on both sides for this purpose.
The network interface is commissioned in the following sequence:
Important!
First clarify the adaptation of IP addresses with your network
administrator for installation with a connection to an existing in-house
network.
Assign a
Home network address
for connecting the controller to an
existing home network (e.g. 10.208.3.212)
Change the Windows side address of the "RTOS Virtual Network".
If possible, the default scheme (e.g. 192.168.xxx.1) should be
maintained!
Change the network settings (routing) on the programming PC to
communicate with the controller via the Home network (e.g. programming
with MULTIPROG)