61/90
User manual SCAIME:
NU-Soft-eNod4F-E-0716_235704-C.doc
bits
meaning
note
01
net
protocols, no effect otherwise
10
factory calibrated measurement
bits
meaning
note
b11 b10 b9 b8
(or b3 b2 b1 b0 in CANopen®)
input 2 (and input 4 if IO+ version) assignment
0000
none
the input has no function
0001
tare
equivalent to the functions described in
§ functional commands
0010
zero
0011
cancel tare
0100
transmit measurement
*/
send TPDO3**
data is transmitted on the bus at every
rising or falling edge (depending on the
chosen logical)
Transmitter mode only
0101
Continuous transmit measurement
*
Data is transmitted on the bus while
the input is maintained at the right
level (depending on the chosen logical).
Transmission rate is fixed by the
measurement transmission period
setting
0110
Dynamic zero
Same like equivalent functional
command describe in § functional
commands
0111
Start / Stop refilling**
Not directly equivalent compared to
functional commands
1000
Start / Stop hopper emptying**
Not directly equivalent compared to
functional commands
1001
Start/Stop dosing**
Not directly equivalent compared to
functional commands
1010
Suspend / Resume batch**
Not directly equivalent compared to
functional commands
1011
Emergency stop
There is no associated functional
command
1100
Clear totalization and errors counter
Same like equivalent functional
command describe in § functional
commands
1101
Sensor input control
Same like equivalent functional
command describe in § functional
commands
b
12
(or b
4
in CANopen®)
input 2&4 logical
0
negative logic
defines the edge (or level) that triggers
input 1 function
1
positive logic