28/90
User manual SCAIME:
NU-Soft-eNod4F-E-0716_235704-C.doc
5.9.9
0x1017 / 0x00 : Heartbeat producer time
•
access : R/W
•
data type : unsigned16
•
default value : 0
•
mappable ? : N
•
admitted values : from 0 up to 65535
Description:
If a period different from 0 is written into this index,
eNod4
periodically generates a Heartbeat frame. It is
expressed in ms and must be comprised between 1 and 65535.
5.9.10
0x4800 : Safety mode
•
access : R/W
•
data type : unsigned8
•
default value : 0H
•
admitted values : see table below
Description:
This entry defines
eNod4
functioning when in stopped NMT state. The safety mode is used when the bit
b0 of the byte is set to 1. The functioning mode is then inhibited and outputs logical level are given by b1, b2, b3 and
b4 bits. The
eNod4
leaves the safety mode upon reception of a new NMT command.
Warning:
In safety mode, when the
eNod4
is in stopped NMT state, functioning is also
inhibited using Modbus and SCMBus communication. For example, it is not possible to tare or make a zero using RS
485 AUX port, or eNodView connected via USB.
b0
Effect
Notes
0
safety mode disabled
only valid in stopped state
No action possible also using
Modbus or SCMBus
communication
1
safety mode enabled
b1
0
output 1 inhibited
depending on the chosen logic
1
output 1 set active
b2
0
output 2 inhibited
depending on the chosen logic
1
output 2 set active
b3
0
output 3 inhibited
depending on the chosen logic
1
output 3 set active
b2
0
output 4 inhibited
depending on the chosen logic
1
output 4 set active
5.9.11
Error behavior
Sub-index
Description
Access
Default value
Mappable
(PDO) ?
Type
0x00
Number of error
classes
LS
1
N
unsigned 8
0x01
communication
error
L/ E
0
N
unsigned 8