26/90
User manual SCAIME:
NU-Soft-eNod4F-E-0716_235704-C.doc
5.9.1
0x1001 / 0x00 : error register
•
access : RO
•
data type : unsigned8
•
default value : 0
•
mappable ? : N
•
admitted values : see table below
Description:
The device internal errors are indicated by flag bits of this byte. b
0
bit (generic error) is set to 1 if at least
one error is detected.
Bit se to 1
Meaning
b
0
generic error detected
b
1
reserved (0)
b
2
A/D converter input voltage error
b
3
reserved (0)
b
4
CAN bus communication error
b
5
reserved (0)
b
6
reserved (0)
b
7
EEPROM error
5.9.2
0x1003 : Pre-defined error field
Sub-index
Description
Access
Default value
Mappable
(PDO) ?
Type
0x00
reported errors
counter
R/W
0
N
unsigned8
0x01
last reported error
RO
0
N
unsigned32
Description:
This entry of the object dictionary stores the errors that have been reported by emergency telegrams.
The reported errors counter (sub-index 00
H
) is accessible through write or read request but 0 is the only allowed value
for writing transactions. By writing a zero to this sub-index, the error counter is reset and the last reported error (sub
index 01
H
) is erased. An attempt to write another value is ignored and
eNod4
answers the SDO abort code
0x06090030.
5.9.3
0x1005 / 0x00 : synchronization messages COB-ID
•
access : R/W
•
data type : unsigned32
•
default value : 0x80
•
mappable ? : N
•
admitted values : 0x80 or from 0x7E0 up to to 0x7E3
Description:
This object contains the message COB-ID value supported by
eNod4
as synchronization messages (used
for PDO activating).
5.9.4
0x100C / 0x00 : guard time
•
access : R/W
•
data type : unsigned16
•
default value : 0
•
mappable ? : N
•
admitted values : from 0 up to 65535