43/90
User manual SCAIME:
NU-Soft-eNod4F-E-0716_235704-C.doc
10.2
Functional commands list
Functional command
Command
code
Note
Set to idle (00
H
) response register
00
H
See § above
reset*
D0
H
EEPROM storage
D1
H
Restore default settings
D2
H
Zero*
D3
H
Tare*
D4
H
Cancel tare*
D5
H
Cancel current command
D6
H
Theoretical scaling
D7
H
Zero adjustment
D8
H
Start physical calibration
D9
H
physical calibration procedure
Calibration zero acquisition
DA
H
Segment 1 acquisition
DB
H
Segment 2 acquisition
DC
H
Segment 3 acquisition
DD
H
Store calibration
DE
H
e
nd of calibration (physical/theoretical)
procedure
OUT1 activation/deactivation*
E6
H
only possible if the outputs are assigned to
the associated function
OUT2 activation/deactivation*
E7
H
OUT3 activation/deactivation*
E8
H
OUT4 activation/deactivation*
E9
H
zero offset adjustment
F0
H
Dynamic zero acquisition
F1
H
Preset tare*
F2
H
Sensor input reference
EF
H
Sensor input control
FD
H
Totalization / errors clear
DF
H
Dosing / batch start / resume
E4
H
Dosing / batch stop / cancel
E5
H
Suspend batch
F7
H
Emptying hopper (cleaning)
F4
H
Refilling start
F5
H