62/90
User manual SCAIME:
NU-Soft-eNod4F-E-0716_235704-C.doc
bits
meaning
note
b
14
b
13
(or b
6
b
5
in CANopen®)
measurement to be transmitted
00
gross
only for SCMBus/fast SCMBus
protocols, no effect otherwise
01
net
10
factory calibrated measurement
** these commands operates on front in a bistable functioning mode. For example for the Start/Stop refilling
command, the first front initiates refilling, the second stops it.
Note 1:
the functions with a
*
only are possible
in SCMBus and fast SCMBus protocols.
Note 2:
in CANopen® communication protocol, to use the
‘send TPDOX’
function, it is necessary to configure the TPDO
communication parameters (and particularly the communication type) and the mapping for the corresponding TPDO.
13.2.2
Holding time (debounced time)
The holding time (de-bounced time) corresponds to the minimum required stabilization time of the logical inputs
before their activation. If the input level varies within this interval, it is ignored.