87/90
User manual SCAIME:
NU-Soft-eNod4F-E-0716_235704-C.doc
Chapter
Name
Modbus
address
CANopen®
Index/sub-index
Profibus
cyclic
IN/OUT
Acyclic
DPV1
slot/index
Type Access
Dosing
Calibration of flow rate
point 1 (control output
value)
0x0A00 0x470A / 0x01
R : 0x02B4
W: 0x02B5
0x07 / 0x20 Uint
RW
Dosing
Calibration of flow rate
point 2 (control output
value)
0x0A01 0x470A / 0x02
R : 0x02B6
W: 0x02B7
0x07 / 0x21 Uint
RW
Dosing
Calibration of flow rate
point 3 (control output
value)
0x0A02 0x470A / 0x03
R : 0x02B8
W: 0x02B9
0x07 / 0x22 Uint
RW
Dosing
Calibration of flow rate
point 4 (control output
value)
0x0A03 0x470A / 0x04
R : 0x02BA
W: 0x02BB
0x07 / 0x23 Uint
RW
Dosing
Calibration of flow rate
point 5 (control output
value)
0x0A04 0x470A / 0x05
R : 0x02BC
W: 0x02BD
0x07 / 0x24 Uint
RW
Dosing
Calibration of flow rate
point 6 (control output
value)
0x0A05 0x470A / 0x06
R : 0x02BE
W: 0x02BF
0x07 / 0x25 Uint
RW
Dosing
Calibration of flow rate
point 7 (control output
value)
0x0A06 0x470A / 0x07
R : 0x02C0
W: 0x02C1
0x07 / 0x26 Uint
RW
Dosing
Calibration of flow rate
point 8 (control output
value)
0x0A07 0x470A / 0x08
R : 0x02C2
W: 0x02C3
0x07 / 0x27 Uint
RW
Dosing
Calibration of flow rate
point 9 (control output
value)
0x0A08 0x470A / 0x09
R : 0x02C6
W: 0x02C7
0x07 / 0x28 Uint
RW
Dosing
Calibration of flow rate
point 10 (control output
value)
0x0A09 0x470A / 0x0A
R : 0x02C8
W: 0x02C9
0x07 / 0x29 Uint
RW
Dosing
Calibration of flow rate
point 1
(flow rate value)
0x0A0A 0x470B / 0x01
R : 0x04CA
W: 0x04CB
0x07 / 0x2A float
RW
Dosing
Calibration of flow rate
point 2
(flow rate value)
0x0A0C 0x470B / 0x02
R : 0x04CC
W: 0x04CD
0x07 / 0x2B float
RW
Dosing
Calibration of flow rate
point 3
(flow rate value)
0x0A0E 0x470B / 0x03
R : 0x04CE
W: 0x04CF
0x07 / 0x2C float
RW
Dosing
Calibration of flow rate
point 4
(flow rate value)
0x0A10 0x470B / 0x04
R : 0x04D0
W: 0x04D1
0x07 / 0x2D float
RW