The available functions are:
function
Operating mode
transmitter
Loss in weight feeder
none
●
●
set point
●
●
motion
●
●
defective measurement
●
●
input image
●
●
level on request
●
●
cycle in progress
●
External totalizer
●
Flow rate alarm
●
Batch complete
●
Refilling in progress
●
Extraction activated
●
Volumetric phase
●
•
None :
the output has no function
•
Setpoint :
each output can be assigned to a configurable set point (set point 1 corresponds to output 1, set
point 2 to output 2, set point 3 to output 3 and set point 4 to output 4).
•
Motion :
the output is dedicated to copying the stability flag level.
•
Defective measurement :
the output level is set when the internal alarm flag described in “Weighing
diagnosis” § in the MEASUREMENT AND STATUS § is activated. This allows to warn about defection of the
measurement chain. Flowrate, refilling, empty or full hopper or too long batch alarms are not considered
as defective measurements.
•
Input image :
the output is dedicated to copying a logical input level (outputs 1 and 3 correspond to inputs
1 and 3, outputs 2 and 4 correspond to input 2 and 4).
•
Level on request :
the input level is driven by master requests.
•
Cycle in progress :
in dosing mode, indicates that a dosing cycle is running.
•
External totalizer :
this output is dedicated to deliver pulses for external totalizer device.
If a logical output is assigned to
external totalizer
function,
eNod4
will send a pulse every time totalization
result will reach a multiple of weight value defined in
weight quantity per pulse on logical output
parameter expressed in
weight unit
x1000.
•
Flowrate alarm :
the output is dedicated to copying dosing alarms. Alarms might be flow rate, control
output level, refilling, batch too long, empty hopper, full hopper or external totalizer overflow.
•
Batch complete :
in dosing mode, indicates that a batch is complete.
•
Refilling in progress :
indicates that a refilling process is running.
•
Extraction activated :
in dosing mode, indicates that the extraction device is activated.
•
Volumetric phase :
in dosing mode, indicates volumetric or gravimetric phases.