39/90
User manual SCAIME:
NU-Soft-eNod4F-E-0716_235704-C.doc
9.1.6
Measurement status
The measurement status contains information on eNod4 measurement parameters.
The
‘measurement status’
bytes contain information about every measurement processed by
eNod4
. See the flags
meaning in the table below:
bits
Meaning
Note
b
1
b
0
00
gross measurement
only in SCMBus/fast communication
protocols
not significant otherwise (00)
01
net measurement
10
factory calibrated measurement
11
tare value
b
3
b
2
00
measurement OK
01
Defect: sensor input control result out of
tolerances OR Sensor input control
command in progress OR failed (timeout)
OR Sensor input reference command in
progress
causes a logical output assigned to the
‘defective measurement’ function to be
set active. Causes the analog output
assigned to a weight or flow rate
image to be set in error mode.
10
gross meas.< (- max capacity) OR gross
meas. > (max capacity)
11
analog signal out of the A/D converter input
range
b
4
0
motion
causes an output assigned to the
‘motion’ function to be set active
1
no motion
b
5
0
measurement out of the ¼ of division
1
zero in the ¼ of division
b
6
0
EEPROM OK
See Note 1
1
EEPROM failure
b
7
0
reserved
1 in SCMBus and fast SCMBus, 0
otherwise
1
b
8
0
IN1 logical level
1
b
9
0
IN2 logical level
1