84/90
User manual SCAIME:
NU-Soft-eNod4F-E-0716_235704-C.doc
Chapter
Name
Modbus
address
CANopen®
Index/sub-index
Profibus
cyclic
IN/OUT
Acyclic
DPV1
slot/index
Type Access
Dosing
Max permissible flow rate
control output
0x0071
0x4704 / 0x04
R : 0x029E
W: 0x029F
0x07 / 0x15 Uint
RW
Dosing
Inhibit time of flow rates
alarms at start
0x0072
0x4704 / 0x05
R : 0x02A0
W: 0x02A1
0x07 / 0x16 Uint
RW
Dosing
Inhibit time of flow rates
alarms in service
0x0073
0x4704 / 0x06
R : 0x02A2
W: 0x02A3
0x07 / 0x17 Uint
RW
Dosing
Maximum batch time
0x0074
0x4704 / 0x07
R : 0x02A4
W: 0x02A5
0x07 / 0x18 Uint
RW
Dosing
Weight to totalize (Great
WU)
0x0075
0x4705 / 0x01
R : 0x04A6
W: 0x04A7
0x07 / 0x19 Ulong RW
Dosing
Complementary weight to
totalize
0x0077
0x4705 / 0x02
R : 0x02A8
W: 0x02A9
0x07 / 0x1A Uint
RW
Dosing
Weight to totalize inflight
value
0x0078
0x4705 / 0x03
R : 0x04AA
W: 0x04AB
0x07 / 0x1B long
RW
Dosing
Nominal flow rate
0x007A 0x4706 / 0x00
R : 0x04AC
W: 0x04AD
0x07 / 0x1C float
RW
Reserved (2 bytes)
0x007C
Measures
Measurement status
0x007D 0x5003 / 0x00 (M)
Module 1
(2 first
bytes)
/
Uint
RO
Measures
Gross measurement
0x007E
0x5001 / 0x00 (M)
Module 1
(4 last
bytes)
/
Long
RO
Measures
Tare value
0x0080
0x5004 / 0x01 (M) R 0x0470
/
Long
RO
Measures
Net measurement
0x0082
0x5000 / 0x00 (M)
Module 2
(4 bytes
from 3rd)
/
Long
RO
Measures
Factory calibrated points
0x0084
0x5002 / 0x00 (M)
Module 2
(4 last
bytes)
/
Long
RO
Dosing
Instant flow rate
0x0086
0x5005 / 0x01 (M)
R : 0x0400
+ See
modules list
/
float
RO
Dosing
Average flow rate
0x0088
0x5005 / 0x02 (M)
R : 0x046E
+ See
modules list
/
float
RO
Dosing
Flow rate control output
0x008A 0x5005 / 0x03 (M)
R : 0x04EA
+ See
modules list
/
float
RO
Dosing
Control output value
0x008C
0x5005 / 0x04 (M)
R : 0x02EC
+ See
modules list
/
Uint
RO