83/90
User manual SCAIME:
NU-Soft-eNod4F-E-0716_235704-C.doc
Chapter
Name
Modbus
address
CANopen®
Index/sub-index
Profibus
cyclic
IN/OUT
Acyclic
DPV1
slot/index
Type Access
Dosing
Instant flow rate
determination time
0x0058
0x4700 / 0x01
R : 0x0274
W: 0x0275
0x07 / 0x00 Uint
RW
Filtering
Average flow rate
determination depth
0x0059
0x4700 / 0x03
R : 0x0278
W: 0x0279
0x07 / 0x02
Uint
RW
Metrology
Flow rate time unit
0x005A 0x3700 / 0x03
R : 0x021E
W: 0x021F
0x01 / 0x06 Uint
RW
Measures
Dynamic zero acquisition
time
0x005B
0x4708 / 0x00
R 0x02B0
W 0x02B1
0x07 / 0x1E Uint
RW
Dosing
Learning cycle end of refill
delay
0x005C
0x4701 / 0x01
R : 0x027A
W: 0x027B
0x07 / 0x03 Uint
RW
Dosing
Learning cycle flow rates
reference determination
time
0x005D 0x4701 / 0x02
R : 0x027C
W: 0x027D
0x07 / 0x04 Uint
RW
Dosing
End of refill and cycle start
stabilization time
0x005E
0x4701 / 0x03
R : 0x027E
W: 0x027F
0x07 / 0x05 Uint
RW
Dosing
Cycle and alarm options
0x005F
0x4701 / 0x04
R : 0x0280
W: 0x0281
0x07 / 0x06 Uint
RW
Dosing
Refilling low level
0x0060
0x4701 / 0x05
R : 0x0482
W: 0x0483
0x07 / 0x07 Ulong RW
Dosing
Refilling high level
0x0062
0x4701 / 0x06
R : 0x0484
W: 0x0485
0x07 / 0x08 Ulong RW
Dosing
Refilling inflight value
0x0064
0x4701 / 0x07
R : 0x0486
W: 0x0487
0x07 / 0x09 long
RW
Dosing
Fixed flow rate during
refilling
0x0066
0x4701 / 0x08
R : 0x0488
W: 0x0489
0x07 / 0x0A float
RW
Dosing
Empty hopper level
0x0068
0x4702 / 0x01
R : 0x048E
W: 0x048F
0x07 / 0x0D Ulong RW
Reserved (2 bytes)
0x006A
Dosing
Maximum time for
refilling start
0x006B
0x4703 / 0x01
R : 0x0290
W: 0x0291
0x07 / 0x0E Uint
RW
Dosing
Time interval for weight
variation control on
refilling
0x006C
0x4703 / 0x02
R : 0x0294
W: 0x0295
0x07 / 0x10 Uint
RW
Dosing
Maximum refilling time
0x006D 0x4703 / 0x03
R : 0x0296
W: 0x0297
0x07 / 0x11 Uint
RW
Dosing
Min permissible instant
flow rate
0x006E
0x4704 / 0x01
R : 0x0298
W: 0x0299
0x07 / 0x12 Uint
RW
Dosing
Max permissible instant
flow rate
0x006F
0x4704 / 0x02
R : 0x029A
W: 0x029B
0x07 / 0x13 Uint
RW
Dosing
Min permissible flow rate
control output
0x0070
0x4704 / 0x03
R : 0x029C
W: 0x029D
0x07 / 0x14 Uint
RW