Section 3: Configuration
XL400/410e Operator’s Manual
Page 3-13
3.5 SERVICE MODE (CONT’D)
3. Calculate the starting point voltage using the formula.
4. Use the START/STOP key to step the counter to the desired setting. The display will
increment one step for each time the START/STOP key is pressed. If the START/STOP key
is held pressed for more than two seconds, it will automatically go into the fast scroll mode.
The reading will advance to a setting of 4.9 (the maximum voltage) after which it will
automatically wrap and start at “0.0” again. If a value of “0.0” is set, the printer will
automatically set the level half way between the two measured voltages each time the
printer is powered on with labels loaded.
5. Repeat this procedure using values slightly higher or lower until the optimum performance is
obtained. If you cannot find a setting between the high and low readings that gives adequate
performance, then the label stock has too much variation in its opacity and a better quality
stock should be used.
6. Once the setting is correct, pressing the FEED key will advance to the next display.
I-Mark: When setting the “I-Mark” threshold, the voltage must be measured with nothing but
the label or tag under the sensor and then again with the printed I-Mark under the sensor.
The smaller value is added to the larger and the result multiplied by 0.5. This is the starting
point to be used. The formula for this is:
(High Voltage Level + Low Voltage Level) x 0.5 = Start Value
1. Insert a label or tag into the sensor (see Section 4: Cleaning and Maintenance for
location of the sensors) and close the Media Hold Down. Make sure the printed I-Mark
is not under the sensor. Record the voltage shown on the top line of the LCD panel.
This line should have the message “I-Mark” on the top line.
2. Now pull the label or tag forward until the I-Mark is positioned under the sensor (the
voltage reading should be at its highest point). Record the voltage shown on the top line
of the LCD panel. The voltage ranges measured should be within the following ranges:
If the measured values are outside this range, you may have trouble in finding a value
that will work properly under all conditions. If this is the case, a higher quality label
may be needed to get adequate performance.
3. Calculate the starting point voltage using the formula.
Label or Tag only
I-Mark
Less than 1.0V
2.5V to 3.5V
Содержание XL 410e
Страница 1: ...XL400e 410e OPERATOR S MANUAL...
Страница 12: ...Section 1 Introduction Page 1 8 XL400 410e Operator s Manual This page has been left blank intentionally...
Страница 23: ...Section 2 Installation XL400 410e Operator s Manual Page 2 11 2 8 SENSOR POSITIONS...
Страница 56: ...Section 3 Configuration Page 3 22 XL400 410e Operator s Manual This page has been left blank intentionally...