Section 3: Configuration
Page 3-2
XL400/410e Operator’s Manual
3.1 PRINTER DIP SWITCH CONFIGURATION
DIP Switch Panels
Three DIP switches (DSW1, DSW2 and DSW3) are located underneath an access panel inside
the printer. These switches can be used to set:
• RS232C transmit/receive parameters
• Thermal transfer or direct thermal mode
• Head check mode
• Hex dump mode
• Receive buffer size
• Operation mode
Each switch is an eight section “toggle” switch. The ON position is always to the top (up). To set
the switches, first turn the unit Off, then position the DIP switches. After placing the switches in
the desired positions, turn the printer back on. The switch settings are read by the printer
electronics during the power up sequence. The settings will not become effective until the power
is cycled.
RS232 Transmit/Receive Setting
Data Bit Selection (DSW1-1): This switch sets the printer to receive either 7 or 8 bit data bits for
each byte transmitted.
Parity Selection (DSW1-2, DSW1-3): These switches select the type of parity used for error
detection.
DSW1-1
Setting
Off
8 data bits
On
7 data bits
DSW1
ON
OFF
1
2
3
4
5
6
7
8
DSW1-1
DSW1-3
Setting
Off
Off
No Parity
Off
On
Even
On
Off
Odd
On
On
Not Used
DSW1
ON
OFF
1
2
3
4
5
6
7
8
Содержание XL 410e
Страница 1: ...XL400e 410e OPERATOR S MANUAL...
Страница 12: ...Section 1 Introduction Page 1 8 XL400 410e Operator s Manual This page has been left blank intentionally...
Страница 23: ...Section 2 Installation XL400 410e Operator s Manual Page 2 11 2 8 SENSOR POSITIONS...
Страница 56: ...Section 3 Configuration Page 3 22 XL400 410e Operator s Manual This page has been left blank intentionally...