SECTION 2: INSTALLATION
Page 2-18
XL400/410e Operator’s Manual
2.11 CUT SENSOR ADJUSTMENT
These adjustments are for R-Corner Tag (Side-Notch), Center-Hole and Edge-Hole tags only.
Lift up the cover. The Cut Sensors are located on an adjustable
assembly that must be correctly positioned for the type of media used.
They must be adjusted correctly even though the Cutter is disabled. If
they are not, a “Cutter Error” will result when you try to feed tags.
COVER
CUTTER
SENSOR
ASSEMBLY
Loosen the green Sensor Adjustment Thumbscrew on the Cutter Sensor
assembly. Align the notch on the Cutter Sensor Assembly to the position
of the tag registration mark using the scale.
SENSOR
ADJUSTMENT
THUMBSCREW