110
SANTERNO
USER MANUAL
Line
Name
Nature
Mod
address
PLC
address
Parameter description
83
Motor rated speed
R/W
52H
40083
0~3600RPM
84
Motor power factor
R\W
53H
40084
0~1.00
85
Motor pole pair
R\W
54H
40085
1-16
86
Motor no-load current
R\W
55H
40086
1~1600.0A
87
Motor stator resistance
R\W
56H
40087
0.001~10.000Ω
88
Motor stator inductance
R\W
57H
40088
0.1~1000.0mH
89
Motor rotor time constant R\W
58H
40089
0.1~30.00s
81
Motor rated current
R/W
50H
40081
0.1~1600.0A
82
Motor rated frequency
R/W
51H
40082
5.00~80.00Hz
83
Motor rated speed
R/W
52H
40083
0~3600RPM
84
Motor power factor
R\W
53H
40084
0~1.00
85
Motor pole pair
R\W
54H
40085
1-16
86
Motor no-load current
R\W
55H
40086
1~1600.0A
87
Motor stator resistance
R\W
56H
40087
0.001~10.000Ω
88
Motor stator inductance
R\W
57H
40088
0.1~1000.0mH
89
Motor rotor time constant R\W
58H
40089
0.1~30.00s
90
Magnetic flux set
R\W
59H
40090
1.0~1600.0A
91
Speed proportion
coefficient
R\W
5AH
40091
0.5~20.00
92
Speed integral time
R\W
5BH
40092
0.1~20.00s
93
Magnetic flux proportion
R\W
5CH
40093
0.5~20.00
94
Magnetic flux integral
R\W
5DH
40094
0.1~20.00s
95
Current loop proportion
coefficient
R\W
5EH
40095
0.1~15.00
96 Current loop integral time R\W
5FH
40096
0.15~30.00ms
97
Encoder pulse number
R\W
60H
40097
0:512 1:1024 2:2048 3:4096 4:8192 5:16384 6:65535
98
Rotor position value
R\W
61H
40098
0~16384
99
Motor rotation direction
R\W
62H
40099
0:reverse 1:forward
100
S curve
R\W
63H
40100
High byte: curve parameter1 low byte: curve parameter 2
101
Difference between
master and slave
frequency
R\W
64H
40101
10
Excitation parameter
102 Parameter combination 7 R\W
65H
Bit
Name
0
1
15
14
13
12
11