62
SANTERNO
USER MANUAL
ID
Description
Unit
Min.
Max.
Default VFD type Valid
6
VFD current limit coefficient: the
current limit proportion of VFD
output current
V
10
200
100
1. General VFD For async motor
2. SVC VFD for async motor
3. General VFD for sync motor
4. SVC VFD for sync motor
5. Openloop VC VFD for async motor
6 .Openloop VC VFD for sync motor
7
Motor rated voltage: rated
voltage on motor nameplate
A
380
15000
6000
1. General VFD For async motor
2. SVC VFD for async motor
3. General VFD for sync motor
4. SVC VFD for sync motor
5. Openloop VC VFD for async motor
6. Openloop VC VFD for sync motor
8
Motor rated current: rated
current on motor nameplate
Hz
1
1600
77
1. General VFD For async motor
2. SVC VFD for async motor
3. General VFD for sync motor
4. SVC VFD for sync motor
5. Openloop VC VFD for async motor
6. Openloop VC VFD for sync motor
9
Motor rated frequency: rated
frequency value on motor
nameplate
rpm
5
80
50
1. General VFD For async motor
2. SVC VFD for async motor
3. General VFD for sync motor
4. SVC VFD for sync motor
5. Openloop VC VFD for async motor
6. Openloop VC VFD for sync motor
10
Motor rated speed: rated speed
value on the motor nameplate
0
3600
980
1. General VFD For async motor
2. SVC VFD for async motor
3. General VFD for sync motor
4. SVC VFD for sync motor
5. Openloop VC VFD for async motor
6. Openloop VC VFD for sync motor
11
Motor power factor
0
1.0
0.9
1. General VFD For async motor
2. SVC VFD for async motor
3. General VFD for sync motor
4. SVC VFD for sync motor
5. Openloop VC VFD for async motor
6. Openloop VC VFD for sync motor
12
Motor pole pair numbers:
2: the pole pair number on
the motor nameplate, used
to calculate motor rated slip
difference
4: the pole pair number on the
motor nameplate, used to
calculate motor rated speed
5: Obtained by motor parameter
identification
pair
1
36
3
2. SVC VFD for async motor
4. SVC VFD for sync motor
5. Openloop VC VFD for async motor