5
Setup Tools
Setup Tools includes options to load or save parameters to a backup file, set the starter's network address, check the status of the
inputs and outputs, reset the thermal models or test operation using the Run Simulation.
To access the Setup Tools, press
MENU
to open the Menu then select Setup Tools.
5.1
Set Date and Time
To set the date and time:
1.
Press
MENU
to open the menu then select Setup Tools.
2.
Scroll to Set Date & Time.
3.
Press the button to enter edit mode.
4.
Press the and buttons to select which part of the date or time to edit.
5.
Use the and buttons to change the value.
6.
Press after the last digit to save the setting. When the action has been completed, the screen will briefly display a confirmation
message, then return to the previous menu level.
5.2
Command Source
The ASA 4.0 Advanced can be started and stopped via the digital inputs, remote keypad, communication network, smart card or
scheduled auto-start/stop. The command source can be set via the Setup Tools, or using parameter 1A
Command Source
.
If the remote keypad is installed, the
LOCAL/REMOTE
button provides shortcut access to the Command Source function in Setup
Tools.
5.3
Commissioning
Commissioning lets the starter be started and stopped via the local keypad. Use the and buttons to select a function, then press
to send the selected command to the starter. The available functions are:
•
Quick stop (coast to stop)/Reset
•
Start
•
Stop
5.4
Run simulation
The run simulation simulates a motor starting, running and stopping to confirm that the soft starter and associated equipment have been
installed correctly.
NOTE
The soft starter must be disconnected from mains voltage.
The simulation is only available when the soft starter is in Ready state.
To use the run simulation:
1.
Press
MENU
to open the menu then select Setup Tools.
2.
Scroll to Run Simulation and press .
Run Simulation
Ready
Apply Start Signal
3.
Apply a start command from the selected command source. The ASA 4.0
Advanced simulates its pre-start checks and closes the main contactor relay. The
Run LED flashes.
Run Simulation
Pre-Start Checks
MENU to Continue
NOTE
If mains voltage is connected, an error message is shown.
Run Simulation
ATTENTION!
Remove Mains Volts
MENU to Continue
4.
Press . The ASA 4.0 Advanced simulates starting. The Run LED flashes.
Run Simulation
Starting X:XXs
MENU to Continue
5.
Press . The ASA 4.0 Advanced simulates running.
Run Simulation
Running
Apply Stop Signal
24/78
ASA 4.0 Advanced
Содержание ASA 4.0 Advanced
Страница 78: ...78 78 ASA 4 0 Advanced ...