7.4 Ethernet Cabling (Optional)
The router can be connected to a local network so that it can be monitored and configured
from one or more remote Workbench computers. Ethernet cables are used to connect the
Door PC and the router controllers to the network.
Connect the Nucleus router control module(s) and router Door PC to a network switch on the
same network as the computer(s) that Workbench is being installed on. For Workbench
installation details see section 11.
If the router control module(s) are shipped loaded with the sample/default database the
default controller and Door PC IP addresses are as listed below.
If the IP addresses don’t suit the host network the network switch and the computer running
Workbench should form an isolated network until the IP addresses are changed to suit the
host network. If the IP Addresses need to be changed see section 7.4.1.
Sirius 830 Default IP Addresses
:
- Controller A - 172.31.9.205
- Controller B - 172.31.9.206
- Door PC - 172.31.9.207
7.4.1 Changing IP Addresses
•
If the controller IP addresses need to be changed, see the Sirius 800 User manual for
details.
•
The Door PC IP address is changed via Windows XP on the Door PC using Windows
remote desktop or by connecting a USB mouse and Keyboard locally. See the Door
PC Maintenance section of the Sirius 800 Maintenance & Upgrade manual for login
and connection details.
Note:
•
If the router is shipped with a custom database the IP addresses may be different
from those listed below. See section 7.4.1 for information on how to check or edit
the IP addresses.
•
By default the Nucleus2 2463 router control module will automatically negotiate its
communication speed with the network switch. If the network switch is set to force
a specific speed the controller must be set to match the network switch setting, see
the Sirius 800 User manual for details on changing this setting 10Base-T or
100Base-T only (1000Base-T is not supported).
Fig 16. Ethernet Connections
Ethernet Hub
Door Ethernet
Port
Ethernet A/B Ports
Содержание Sirius 830
Страница 2: ...Sirius 830 Installation Manual www s a m com Issue 2 Rev 2 Page 2 2016 SAM...
Страница 6: ...Sirius 830 Installation Manual www s a m com About this Manual Issue 2 Rev 2 Page 6 2016 SAM...
Страница 24: ...Sirius 830 Installation Manual www s a m com Installation Issue 2 Rev 2 Page 24 2016 SAM...
Страница 28: ...Sirius 830 Installation Manual www s a m com Rear Connectors Issue 2 Rev 2 Page 28 2016 SAM...
Страница 44: ...Sirius 830 Installation Manual www s a m com Powering the Sirius 830 Issue 2 Rev 2 Page 44 2016 SAM...
Страница 52: ...Sirius 830 Installation Manual www s a m com Testing the Sirius 830 Issue 2 Rev 2 Page 52 2016 SAM...
Страница 72: ...Sirius 830 Installation Manual www s a m com Workbench Issue 2 Rev 2 Page 72 2016 SAM...