5.2 Mounting the Power Supply Shelf into a 19" Rack
The Power Supply Shelf can be placed above, below or remote from the Sirius Frame. The
power supply shelf requires a 2RU space within a rack system.
1.
Place the unit on a suitably specified and installed rack shelf.
2.
Use the correct rack mount screws or bolts to secure the power supply shelf to the
rack.
•
The Power Supply Shelf weighs 24 kg (53lb). When lifting use the correct local
Health and Safety lifting guidelines.
•
Do not obstruct the air vents situated on both sides of the power supply shelf, and
allow a minimum of 50 mm (2 inches) clearance to allow air flow. The air that is
exhausted from the sides must be able to flow past the rear of the rack without
being obstructed.
Fig 10. Mounting the Power Supply Shelf into a 19" Rack