Tel: 886. 909 602 109 Email: [email protected]
4
configuration
S3602B-401
4-Port Programmable Step
Attenuator
Set four 70dB programmable step attenuators for the
source path, and four 35dB programmable step
attenuators for the receiver path (Option 400 is
needed)
S3602B-402
Active Inter-modulation
Measurement
For inter-modulation signal measurement of
amplifier (Option 400, S80 is needed)
S3602B-003
Vector Noise Figure
Measurement
The built-in 10MHz-26.5GHz high-sensitivity noise
receiver requires external electronic calibration
components. Using advanced source matching error
and vector error correction calibration techniques,
the industry's highest noise figure measurement
accuracy can be obtained. This option contains
"Scalar Noise Figure Measurement" functions.
S3602B-008
Pulse Measurement
For pulse S-parameter measurement
S3602B-3648
Multi-port Network Parameter
Expansion Device
Extended to 16-port network parameter
measurement (10MHz-26.5GHz)
S3602B-S05
S-parameter Signal Integrity
Analysis
Used to display the frequency domain characteristics
and time domain TDR characteristics of the system.
Built-in crosstalk evaluation modules such as
NEXT, FEXT, PSXT, ILD, ICR and ICN. Built-in
standards such as IEEE 802.3, PCIe, SAS and
SATA help to quickly evaluate whether S
parameters Meet the design requirements. Can
automatically convert the software graphic curve
into Word or PPT report. Support a variety of Dk/Df
extraction methods. Support NRZ, PAM-4 eye
diagram drawing function.
S3602B-S06
MiliMeter Extension Port Power
Control
Special for Saluki VNA. Suitable for extension
modules with power adjustable function such as
3643P S-parameter extension module.
S3602B-S07
AFR Automatic Fixture
Removal Option
Used for automatic testing and removal of single-
ended and balanced device measurement fixtures.
S3602B-S10
Time Domain Measurement
For time-domain test, can locate and analyze the
discontinuous positions in devices, fixtures or
cables.
S3602B-S11
Advanced Time Domain
Analysis
Used for TDR time domain impedance test, eye
diagram analysis, etc.. S10 option is included in
S11.
S3602B-S80
Frequency Offset Measurement
For frequency offset measurement. millimeter-wave
frequency extension main unit needs this option
S3602B-S82
Mixer Scalar Measurement
For the scalar parameter measurement of mixers
(Option 400, S80 is needed)
S3602B-S83
Mixer Vector Measurement
For the vector parameter measurement of mixers
Содержание S3602 Series
Страница 1: ...S3602 Series Vector Network Analyzer Quick Start Guide Saluki Technology Inc...
Страница 30: ...Tel 886 909 602 109 Email sales salukitec com www salukitec com 30 Fig 3 24 Use of Torque Wrench...
Страница 33: ...Tel 886 909 602 109 Email sales salukitec com www salukitec com 33 Fig 4 4 System Recovery Screen...