Tel: 886. 909 602 109 Email: [email protected]
61
Fig. 6-23 Smith Chart Format
a) The horizontal axis of the center of Smith chart represents the pure resistance, and the center of the
horizontal axis represents the system impedance. The leftmost resistance on the horizontal axis is zero,
indicating a short circuit. The rightmost resistance of the horizontal axis is infinite, indicating an open circuit.
b) The points on the intersecting circle of Smith chart and horizontal axis have the same resistance.
c) The points on the tangent of Smith chart and horizontal axis have the same reactance.
d) The reactance of the upper part of Smith chart is positive. Therefore, the upper part is the sensitive zone.
e) The reactance of the lower part of Smith chart is negative. Therefore, the lower part is the capacitive zone.
6.7.2 Data Format Setup
Menu path:
[Response] > [Format]
. The
format
sub-menu will pop up.
6.7.3 Scale
The scale refers to the scale of the vertical part of the display grid. In the polar coordinate and Smith chart format,
the scale refers to the full scale of the excircle. The display mode of measurement data on the screen are determined
by scale and format Setups. In the log format, the scale Setup range is 0.001dB/grid to 500dB/grid.
1) Scale Setup
Menu path:
[Response] > [Scale]
. The
scale
sub-menu will pop up.
Set the appropriate scale, reference location and reference level by clicking the corresponding input zone or keys.