Tel: 886. 909 602 109 Email: [email protected]
6
S3602C-3648
Multi-port Network Parameter
Expansion Device
Extended to 16-port network parameter
measurement (10MHz-43.5GHz)
S3602C-S05
S-parameter Signal Integrity
Analysis
Used to display the frequency domain characteristics
and time domain TDR characteristics of the system.
Built-in crosstalk evaluation modules such as
NEXT, FEXT, PSXT, ILD, ICR and ICN. Built-in
standards such as IEEE 802.3, PCIe, SAS and
SATA help to quickly evaluate whether S
parameters Meet the design requirements. Can
automatically convert the software graphic curve
into Word or PPT report. Support a variety of Dk/Df
extraction methods. Support NRZ, PAM-4 eye
diagram drawing function.
S3602C-S06
MiliMeter Extension Port Power
Control
Special for Saluki VNA. Suitable for extension
modules with power adjustable function such as
3643P S-parameter extension module.
S3602C-S07
AFR Automatic Fixture
Removal Option
Used for automatic testing and removal of single-
ended and balanced device measurement fixtures.
S3602C-S10
Time Domain Measurement
For time-domain test, can locate and analyze the
discontinuous positions in devices, fixtures or
cables.
S3602C-S11
Advanced Time Domain
Analysis
Used for TDR time domain impedance test, eye
diagram analysis, etc.. S10 option is included in
S11.
S3602C-S80
Frequency Offset Measurement
For frequency offset measurement. millimeter-wave
frequency extension main unit needs this option
S3602C-S82
Mixer Scalar Measurement
For the scalar parameter measurement of mixers
(Option 400, S80 is needed)
S3602C-S83
Mixer Vector Measurement
For the vector parameter measurement of mixers
(Option 400, S80 is needed)
S3602C-S84
Embedded LO Frequency
Converter Measurement
For the measurement of embedded LO frequency
converters (Option 400, S82 or S83, S80 are needed)
S3602C-S86
Gain Compression Two-
Dimension Sweep Measurement
For the gain compression two-dimension sweep test
of amplifier
S3602C-S88
Phase Scan Option
Used for phase scan measurement (need option
S3602C-400)
31123
2.4mm Calibration Kit
For calibration of the VNA
SCAVNA50FM-
(2.4/2.4)
2.4mm Test Cable
For measurement of the analyzer, 2.4mm (female) to
2.4mm (male)
SCAVNA50FF-
(2.4/2.4)
2.4mm Test Cable
For measurement of the analyzer, 2.4mm (female) to
2.4mm (female)
20404
E-Cal Kit
For calibration of the analyzer (10MHz-50GHz, 2
ports)
Содержание S3602 Series
Страница 1: ...S3602 Series Vector Network Analyzer Quick Start Guide Saluki Technology Inc...
Страница 30: ...Tel 886 909 602 109 Email sales salukitec com www salukitec com 30 Fig 3 24 Use of Torque Wrench...