2. OPERATION
– 72 –
2.18 When the Battery has Discharged
WARNING
• To check and handle the batteries, keep the
engine stopped with the starter switch in the
"
"
position.
• The batteries give off explosive gases. Do not
smoke close to the batteries. Keep flames and
sparks away from the batteries.
• The electrolyte is very corrosive and will harm
your clothing or skin. If the electrolyte has come
into contact with your clothing or skin, flush with
sufficient amount of water. In case the electrolyte
has gotten into your eyes, flush with water and
get medical help.
• To disconnect the battery cables, start with the
negative terminal (earth). When connecting, start
with the positive terminal . Do not allow a metallic
item to bridge between the positive terminal and
machine body. This can generate sparks, causing
an explosion.
• Loose battery terminals can cause sparks. An
explosion will result. When connecting the
terminals, make certain that they are tight.
CAUTION
The power-supply voltage of this machine is 12V.
2.18.1 Connection and disconnection of booster cables
When jump-starting the engine, connect the booster cables as follows:
■
Connection of booster cables
1) Connect one end of the positive booster cable
Ⓐ
to the positive
⊕
terminal of the dead battery on
the machine.
2) Connect the other end of the positive booster
cable to the positive
⊕
terminal of the live power
supply.
3) Connect the negative booster cable
Ⓑ
to the
negative
⊖
terminal of the live power supply.
4) Connect the other end of the negative booster
cable to a good earth ground on the engine block
of the machine.